SNRSTAT

Applicable to: UM621 series, UM681A

Syntax $SNRSTAT,insstatus,odostatus,InstallState,mapstat*cs
Example $SNRSTAT,3,0,0,2*5C
Description Output initialization status
Input/Output Output
Parameter Definition
Parameter Format Description
insstatus INT INS initialization state:
-1 - IMU device failure
0 - Disable
1 - Initialization started
2 - Known installation angle
3 - Initialization completed
odostatus INT Odometer initialization status:
-1 - Odometer device failure
0 - Disable
1 - Initialization of scale factor
2 - Initialization of scale factor completed
3 - Scale factor calibration completed
InstallState INT -1 - IMU device failure, unable to estimate the installation angle
0 - Calibration in progress
1 - The quality of current satellite information is insufficient and better satellite
conditions are needed
2 - The current vehicle mobility conditions are insufficient, and acceleration is required
3 - The current carrier speed is too low, and it is required to increase the speed
mapstat INT -2 - Abnormal map data is detected
-1 - No port is configured to receive MAP information
0 - The port fails to receive MAP information or the MAP information transmission times out
1 - The MAP information is received but not applied to the integrated navigation
2 - The MAP information is received and applied to the integrated navigation
cs U8 Checksum; two hexadecimal characters obtained by calculating an XOR of all characters
between but not including ‘$' to ‘*' in this message